Liquid Cooling Hits Mainstream: 2025 Marks the Tipping Point for AI Infrastructure

Liquid cooling transitions from bleeding-edge to baseline as GPU power densities make air cooling insufficient.

Liquid Cooling Hits Mainstream: 2025 Marks the Tipping Point for AI Infrastructure

Liquid Cooling Hits Mainstream: 2025 Marks the Tipping Point for AI Infrastructure

Dec 10, 2025 Written By Blake Crosley

2025 is the year when liquid cooling tipped from bleeding-edge to baseline. No longer limited to boutique deployments or experimental designs, liquid cooling has become a critical enabler for AI infrastructure.1 The data center immersion cooling market reached $4.87 billion in 2025 and is forecast to reach $11.10 billion by 2030, registering a 17.91% CAGR.2 The shift reflects fundamental changes in GPU power density that make air cooling insufficient for AI workloads.

At the halfway mark of 2025, the liquid cooling transition became operational, strategic, fully capitalized, and embedded in the infrastructure roadmaps of the industry's most ambitious players.3 Hyperscalers like Google, Meta, AWS, and Microsoft are rolling out liquid-cooled environments across their newest facilities due to increased power densities from AI workloads and HPC.4

Power density drivers

GPU power consumption has escalated beyond air cooling capability for dense AI deployments.

Current rack densities

Average data center rack power density increased by 38% from 2022 to 2024, with power densities now pushing 80 kW to 120 kW in AI clusters.5 NVIDIA Blackwell rack designs push peak densities to 132 kW, with future Blackwell Ultra and Rubin servers requiring 250 to 900 kW per rack.6

Air cooling cannot remove heat efficiently at these power densities. The physics of convective heat transfer limit air cooling effectiveness regardless of fan speeds or air handling unit capacity. Liquid cooling provides fundamentally superior heat transfer coefficients enabling high-density operation.

GPU thermal requirements

Modern GPUs require precise temperature control for optimal performance and reliability. Thermal throttling reduces performance when temperatures exceed specifications. Consistent cooling maintains sustained performance under heavy workloads.

Liquid cooling delivers more consistent temperatures than air cooling. Direct-to-chip liquid cooling removes heat at the source rather than relying on air circulation through complex server geometries. The consistency supports predictable performance for demanding AI workloads.

Technology landscape

Multiple liquid cooling technologies address different requirements and deployment contexts.

Direct-to-chip cooling

Direct-to-chip liquid cooling circulates coolant through cold plates attached directly to GPUs and other heat-generating components. The approach provides targeted cooling for highest-power components while maintaining air cooling for lower-power elements.

Supermicro released NVIDIA Blackwell rack-scale solutions with 250 kW coolant distribution units, doubling previous capacity.7 The CDU capacity increase reflects escalating GPU power requirements. Direct-to-chip solutions scale with GPU generations.

Immersion cooling

Single-phase immersion submerges servers in dielectric fluid that absorbs heat through direct contact. The approach eliminates fans and airflow management while providing uniform cooling. Submer's SmartPod achieves 140 kW per rack with PUE between 1.03 and 1.1, compared to global average 1.6 to 1.9 for traditional air-cooled facilities.8

Two-phase immersion boils dielectric fluid on hot surfaces, with vapor condensing for return to the liquid pool. The phase change provides superior heat transfer. Microsoft tested two-phase immersion for AI training clusters, reporting 30% energy efficiency gain and increased hardware reliability.9

Rear-door heat exchangers

Rear-door heat exchangers capture waste heat at rack exhaust, providing transition option for facilities with air-cooled infrastructure. The approach reduces facility cooling load without requiring server-level modifications. The technology bridges air cooling to liquid cooling during facility transitions.

Deployment momentum

Major 2025 deployments demonstrate liquid cooling's mainstream arrival.

Vendor partnerships

In February 2025, Asperitas partnered with Cisco as part of Cisco Engineering Alliance, combining immersion cooling technologies with Cisco's Unified Compute System.10 The partnership validates immersion cooling for enterprise deployments beyond hyperscale.

In February 2025, Submer ventured into data center design, construction, and services to enable AI infrastructure development.11 The expansion from cooling vendor to infrastructure provider reflects liquid cooling's central role in AI data centers.

In March 2025, LiquidStack inaugurated its Carrollton, Texas headquarters, tripling production capacity.12 The capacity expansion responds to demand exceeding previous production capability.

Regional adoption

North America anchors adoption through production-scale rollouts by hyperscale cloud providers. Established data center markets in Virginia, Texas, and Oregon see liquid cooling become standard for new AI-capable facilities.

Asia-Pacific exhibits the steepest growth as Japan, China, and South Korea champion liquid-cooled AI clusters. The region is expected to register the highest CAGR of 23.2% from 2025 to 2030.13 Government AI initiatives drive rapid deployment of liquid-cooled infrastructure.

Planning implications

Organizations planning AI infrastructure should evaluate liquid cooling requirements for current and future deployments.

New facility design

New AI-capable facilities should incorporate liquid cooling infrastructure from design phase. Retrofit is substantially more expensive and disruptive than initial design inclusion. Facility designs should accommodate both direct-to-chip and immersion options.

Cooling distribution unit placement, piping routes, and floor loading for liquid-filled racks require early design decisions. Facility mechanical systems must support liquid cooling heat rejection alongside or replacing traditional chillers.

Existing facility adaptation

Existing facilities face harder decisions about liquid cooling adoption. Retrofit costs and operational disruption must be weighed against continued air cooling with density limitations. Some facilities may not economically support liquid cooling retrofit.

Hybrid approaches deploying liquid cooling for new AI infrastructure while maintaining air cooling for legacy workloads provide transition paths. The hybrid approach limits retrofit scope while enabling AI workload support.

Operational capabilities

Liquid cooling introduces operational requirements beyond traditional data center management. Coolant quality monitoring, leak detection, and specialized maintenance procedures require training and tooling. Operations teams need liquid cooling expertise.

Introl's network of 550 field engineers support organizations implementing liquid cooling infrastructure for AI deployments.14 The company ranked #14 on the 2025 Inc. 5000 with 9,594% three-year growth.15

Professional deployment across 257 global locations ensures liquid cooling best practices regardless of geography.16 Implementation expertise reduces risk during technology transitions.

Decision framework: cooling technology by workload

Rack Density Recommended Cooling Investment Level
<20 kW Air cooling sufficient Standard HVAC
20-50 kW Rear-door heat exchangers Moderate retrofit
50-100 kW Direct-to-chip liquid Significant infrastructure
>100 kW Immersion cooling Purpose-built facility

Actionable steps: 1. Audit current density: Measure actual vs potential rack power consumption 2. Project GPU roadmap: Plan for 2-3x current density within 3 years 3. Evaluate facility constraints: Assess retrofit feasibility vs new construction 4. Build operational expertise: Train teams on liquid cooling operations before deployment

Technology comparison

Technology PUE kW/Rack Retrofit Difficulty Best For
Traditional air 1.6-1.9 <20 N/A Legacy workloads
Rear-door HX 1.3-1.5 20-40 Low Transitional
Direct-to-chip 1.1-1.3 50-250 Moderate GPU clusters
Single-phase immersion 1.03-1.1 100-140 High Max efficiency
Two-phase immersion <1.1 100-200+ High Highest density

Key takeaways

For facility planners: - Liquid cooling market: $4.87B (2025) → $11.1B (2030) at 17.91% CAGR - Air cooling physically insufficient above 50 kW/rack - New AI facilities should incorporate liquid cooling from design phase

For infrastructure teams: - Direct-to-chip: scales with GPU generations, targets hottest components - Immersion: PUE 1.03-1.1 vs 1.6-1.9 for air cooling (30%+ energy savings) - Asia-Pacific growing fastest (23.2% CAGR) driven by government AI initiatives

For procurement: - Supermicro: 250 kW CDU for Blackwell rack-scale solutions - Submer SmartPod: 140 kW/rack at PUE 1.03-1.1 - LiquidStack: tripled production capacity to meet demand

Outlook

Liquid cooling has transitioned from emerging technology to infrastructure baseline for AI deployments. Organizations planning AI infrastructure without liquid cooling capability risk deployment limitations as GPU power continues increasing.

The economic and operational case for liquid cooling strengthens with each GPU generation. Early adoption provides operational experience and avoids rushed transitions when air cooling reaches hard limits. 2025 marks the year when liquid cooling became unavoidable rather than optional for serious AI infrastructure.

References


Category: Infrastructure & Cooling Urgency: High — Technology transition with immediate planning implications Word Count: ~1,800


  1. Data Center Frontier. "Liquid Cooling Comes to a Boil." 2025. https://www.datacenterfrontier.com/cooling/article/55292167/liquid-cooling-comes-to-a-boil-tracking-data-center-investment-innovation-and-infrastructure-at-the-2025-midpoint 

  2. SkyQuest. "Data Center Liquid Immersion Cooling Market Size & Share." 2025. https://www.skyquestt.com/report/data-center-liquid-immersion-cooling-market 

  3. Data Center Frontier. "Liquid Cooling Comes to a Boil." 2025. 

  4. DataCenters.com. "Why Liquid Cooling Is the Future of Hyperscale Data Centers in 2025." 2025. https://www.datacenters.com/news/why-liquid-cooling-is-becoming-the-new-standard-in-hyperscale-facilities 

  5. IEEE Spectrum. "Data Center Liquid Cooling: The AI Heat Solution." 2025. https://spectrum.ieee.org/data-center-liquid-cooling 

  6. TrendForce. "Data Center Power Doubling? Next-Gen Efficiency & Sustainability Guide." 2025. https://www.trendforce.com/insights/data-center-power 

  7. Data Center Frontier. "Liquid Cooling Comes to a Boil." 2025. 

  8. Grand View Research. "Data Center Liquid Immersion Cooling Market Report." 2025. https://www.grandviewresearch.com/industry-analysis/data-center-liquid-immersion-cooling-market-report 

  9. IEEE Spectrum. "Data Center Liquid Cooling: The AI Heat Solution." 2025. 

  10. Data Center Frontier. "Liquid Cooling Comes to a Boil." 2025. 

  11. Data Center Frontier. "Liquid Cooling Comes to a Boil." 2025. 

  12. Data Center Frontier. "Liquid Cooling Comes to a Boil." 2025. 

  13. Grand View Research. "Data Center Liquid Immersion Cooling Market Report." 2025. 

  14. Introl. "Company Overview." Introl. 2025. https://introl.com 

  15. Inc. "Inc. 5000 2025." Inc. Magazine. 2025. 

  16. Introl. "Coverage Area." Introl. 2025. https://introl.com/coverage-area 

Request a Quote_

Tell us about your project and we'll respond within 72 hours.

> TRANSMISSION_COMPLETE

Request Received_

Thank you for your inquiry. Our team will review your request and respond within 72 hours.

QUEUED FOR PROCESSING